Add to Cart
Measurement function | Range | Parameters |
Electric current | 25.0000 mA | Accuracy ± (0.02%RD+0.003%FS) |
Voltage | 25.0000 V | Accuracy ± (0.02%RD+0.003%FS) |
switch | On/off | If the switch has inspection voltage, the voltage range is (1~12)V |
Power Output | DC24V±0.5V | Maximum output current 50mA, overload protection current 120mA |
Pressure range | Accuracy grade① | Accuracy grade② | Accuracy grade③ | Medium | ||||
(-100~0)kPa | 0.02,G | 0.05,G | -- | ④ | ||||
(0~16) kPa | -- | 0.05,G | -- | ④ | ||||
(0~25) kPa | -- | 0.05,G | -- | ④ | ||||
(0~40) kPa | 0.02,G | 0.05,G | -- | ④ | ||||
(0~60) kPa | 0.02,G | 0.05,G | 0.1,A | ④ | ||||
(0~100) kPa | 0.02,G | 0.05,G | 0.1,A | ④ | ||||
(0~160) kPa | 0.02,G | 0.05,G | 0.05,A | ④ | ||||
(0~250) kPa | 0.02,G | 0.05,G | 0.05,A | ④ | ||||
(0~400) kPa | 0.02,G | 0.05,G | 0.05,A | ⑤ | ||||
(0~600) kPa | 0.02,G | 0.05,G | 0.05,A | ⑤ | ||||
(0~1) MPa | 0.02,G | 0.05,G | 0.05,A | ⑤ | ||||
(0~1.6) MPa | 0.02,G | 0.05,G | 0.05,A | ⑤ | ||||
(0~2.5) MPa | 0.02,G | 0.05,G | 0.05,A | ⑤ | ||||
(0~4 )MPa | 0.02,G | 0.05,G | 0.05,A | ⑤ | ||||
(0~6) MPa | 0.02,G | 0.05,G | 0.05,A | ⑤ | ||||
(0~10) MPa | 0.02,SG | 0.05,SG | 0.05,A | ⑤ | ||||
(0~16 )MPa | 0.02,SG | 0.05,SG | 0.05,A | ⑤ | ||||
(0~25)MPa | 0.02,SG | 0.05,SG | 0.05,A | ⑤ | ||||
(0~40) MPa | 0.02,SG | 0.05,SG | 0.05,A | ⑤ | ||||
(0~60) MPa | 0.02,SG | 0.05,SG | 0.05,A | ⑤ | ||||
(0~100) MPa | -- | 0.1/0.2,SG | -- | ⑤ | ||||
(0~160) MPa | -- | 0.1/0.2,SG | -- | ⑤ | ||||
(0~250) MPa | -- | 0.1/0.2,SG | -- | ⑤ | ||||
G=gauge pressure; SG=sealed gauge pressure; A=absolute pressure; temperature range to ensure accuracy: ①(20±5)℃, ②,③(0~50)℃; ④ Compared with glass, ceramic, silicon, room temperature Non-corrosive gas compatible with vulcanized silicon rubber, nickel, gold, aluminum and other materials; ⑤liquid, gas or vapor compatible with 316 stainless steel | | | | |